Chapter 6Appendix — Technical information
ENGLISH - 199
Command transmission method
Transmit using the following command formats.
r Transmitted data
Header Data section
Termination
symbol
Command
example
Hash value
(Refer to “Connecting” above)
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length 32 bytes 1 byte 1 byte Undened length 1 byte
f Example: Transmission of power supply status acquisition command (hash value is calculated from default user
name, password, and acquired random number)
“dbdd2dabd3d4d68c5dd970ec0c29fa6400QPW” (CR)
r Received data
Header Data section
Termination
symbol
Command
example
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length 1 byte 1 byte Undened length 1 byte
f Example: The projector is powered on
“00001” (CR)
r Error response
String Details
Termination
symbol
Message
“ERR1” Undened control command
(CR)
0x0d
“ERR2” Out of parameter range
“ERR3” Busy state or no-acceptable period
“ERR4” Timeout or no-acceptable period
“ERR5” Wrong data length
“ERRA” Password mismatch
Data length 4 bytes 1 byte
When web control administrator rights password is not set (Non-protect mode)
Connecting
1) Obtain the IP address and port number (Initial set value = 1024) of the projector and request a
connection to the projector.
f You can obtain both the IP address and the port number from the menu screen of the projector.
IP address
Obtain from the [NETWORK] menu [NETWORK STATUS].
Port number
Obtain from the [NETWORK] menu [NETWORK CONTROL] [COMMAND PORT].
2) Check the response from the projector.
Data section Blank Mode
Termination
symbol
Command
example
“NTCONTROL”
(ASCII string)
‘ ’
0x20
‘0’
0x30
(CR)
0x0d
Data length 9 bytes 1 byte 1 byte 1 byte
f Mode: 0 = Non-protect mode
f Example: Response during non-protect mode
“NTCONTROL 0” (CR)